CANedge2 (32 GB) – 2x CAN BUS Data Logger with WiFi

$1,180.00

The plug & play 2xCAN/LIN logger records timestamped CAN data (Classical/CAN FD) to the extractable 32 GB industrial SD card. The small device connects via WiFi access points (e.g. WLAN or 3G/4G routers) to securely push data to your server. Further, global fleets can easily be managed via over-the-air firmware & config updates.

-
+

Description

The plug and play 2xCAN/LIN logger records timestamped CAN data (Classical/CAN FD) to the extractable 32 GB industrial SD card (8 GB variant available).

The small device connects via WiFi access points (e.g. WLAN or 3G/4G routers) to securely push data to your server. Further, global fleets can easily be managed via over-the-air firmware & config updates.

The CANedge2 is ideal for telematics & vehicle fleet management – as well as R&D field testing, diagnostics and predictive maintenance of machinery.

Software/APIs are free & open source – with no subscription fees or vendor lock-in.

Reinventing telematics

Today, fleet telematics is vital across vehicles and machines. However, end users face challenges: Expensive subscriptions. No data ownership. Security concerns. Lack of control.

The CANedge2 provides a modern alternative:

  • Simply add your WiFi access point & server details to start.
  • Log data to the SD – auto-upload when connected to WiFi.
  • Configure file split size/period to control upload frequency.
  • 100% secure: HTTPS, credential encryption and more.
  • Over-the-air updates (firmware & configuration).
  • 2nd port can power external modules (e.g. 4G hotspot, GPS).
  • Easily use with local, dedicated & cloud servers.
  • Supports multiple hotspots (e.g. optimize WLAN vs. cellular).
  • No fees. Open source software. Ideal for white label

Features:

  • Dual high speed CAN/LIN (incl. CAN FD) channels
  • Binary MDF4 log file format (extensive software support)
  • Lossless logging at full bus load – with 50 ?s RTC resolution
  • Advanced message filtering & transmit functionality
  • Start/stop logging triggers based on CAN ID & databytes
  • Silent mode, bit rate auto-detection, cyclic logging
  • Extractable 8-32 GB industrial SD card (= months of data)
  • Fast boot time. Safely disconnect during use

Specifications

CAN BUS:

  • Channels: 2 x CAN/CAN FD channels
  • Standard: ISO 11898: Compliant with CAN (up to 1 Mbit/s) and ISO & Bosch CAN FD (up to 5 Mbit/s)
  • Protocols: Log raw data from CAN based protocols (J1939, FMS, CANopen, NMEA 2000, OBD2, …)
  • Identifiers: Compliant with CAN specifications 2.0A (11-Bit ID) and 2.0B (29-Bit ID)
  • Bit-Rate Auto-Detect: Bit rate can be auto-detected or set manually
  • Retransmission: Configurable retransmission of frames that have lost arbitration or been disturbed by errors
  • Transceiver Protection: +/- 16 kV HBM ESD, ?15 kV IEC ESD, ?70 V bus fault, short circuit

LIN BUS:

  • Channels: 2 x LIN channels (Slaves)
  • Standard: Compliant with LIN 2.0 up to 20 Kbit/s (“enhanced” checksum format)
  • Transceiver Protection: +/- 8 kV HBM ESD, +/- 1.5 kV CDM, +/- 58 V bus fault

Data Logging:

  • SD Card: 32 GB extractable Class 10 industrial micro SD (SDHC) included – read at 80 MB/s
  • Parallel CAN/LIN: Record data from up to 2 x CAN channels + 2 x LIN channels, simultaneously
  • Real-Time Clock: Yes – CAN frames are date & timestamped with 50 microsecond resolution. The RTC can be configured to match local time zones (default: UTC)
  • Log File Format: Log data in industry standard binary MDF4 (easily convert to e.g. CSV, ASC, pandas, MATLAB, …)
  • Silent Mode: Configurable silent mode: Restricted (acknowledge only) or monitoring (zero transmission)
  • Filters: 128/64 regular/extended ID filters per channel (range, mask, acceptance, rejection, pre-scaling)
  • Transmit: Transmit lists of CAN frames per channel (single-shot/periodic) – e.g. for OBD2 requests
  • Cyclic Logging: Optional cyclic logging mode (oldest log file is deleted when SD card is full)
  • Advanced Triggers: Control signal lets you start/stop logging based on custom CAN IDs & data thresholds
  • CAN Heartbeat: Optionally transmit heartbeat CAN frame with device status, storage used & RTC time
  • File Split: Configurable log file split size (by size: 1-512 MB and/or by time period: 0-86400s)
  • Power Safe: 100% power safe data logging – no file corruption when disconnected
  • Unique Device ID: Each device has a globally unique ID ensuring unique log file naming
  • Data Encryption: Log files can be encrypted at rest on the SD card for security/GDPR/CCPA purposes [pending FW]

WiFi:

  • Transfer Modes: Station mode: Connects to a WiFi access point (e.g. a router or 3G/4G hotspot) to transfer data
  • Protocol: HTTP/HTTPS: Stable, low overhead transfers – ideal for big data telematics
  • Access Points: Add 1-5 WiFi access points. Prioritized order. Condition on signal strength
  • Over-The-Air (OTA): Configuration & firmware over-the-air (COTA/FOTA). Configurable sync rate. Optionally disable
  • WiFi Heartbeat: If enabled, the CANedge2 periodically “checks-in” by uploading a small device status file
  • Data Upload State: Optionally disable/enable upload of log files (e.g. via over-the-air configuration)
  • Range: Strong range via external WiFi antenna
  • LAN Standard: IEEE 802.11 b / g / n
  • Antenna: External (SMA, 2400 Mhz, <2 dBi gain) – optionally extendable via extension cable
  • Server Interface: Popular S3 REST interface – plug & play with MinIO (open source), AWS, Google Cloud, …

Security:

  • HTTPS: Data & over-the-air updates can be sent via HTTPS (TLS 1.2) for secure transfer
  • WPA/WPA2: Supports WPA/WPA2
  • Credential Encryption: WiFi access point & server credentials can be encrypted in the config on the device SD card
  • Signed Firmware: Firmware updates are digitally signed to verify that they are from a trusted source

General:

  • Functionality: Standalone data logger with SD card and 2xCAN/LIN channels (incl. CAN FD)
  • Firmware: Supports free firmware updates for adding features
  • Configuration: Configuration files based on the popular open source JSON schema concept
  • Software: Free open source editor tool for easy device configuration (offline/online version available), Free open source asammdf software & API for editing, DBC converting & plotting MDF4 data, Free open source C++ MDF4 converters – drag & drop log files to convert into e.g. CSV, ASC, PCAP
  • Safety: CE, FCC, IC and RoHS certified (see the manual). Tested for voltage transients (emissions/immunity), ISO 7637-2:2011, by T?V S?D (see the manual)
  • Warranty: 1-year warranty
  • Support: Free, fast & high quality support
  • Origin: Denmark